You are here > Residential > Resins and Media > Filox-R

Filox-R™

Iron, Hydrogen Sulfide, and Manganese Removal

Filox-R™ Media
Filox-R™ media is an economical Iron and Hydrogen Sulfide filtration media that out performs traditional Greensand and Birm.


Features & Benefits

  • Superior high efficiency media for filtration and removal capabilities
  • No oxidizing chemicals needed for regeneration.
  • High efficiency with 80% manganese dioxide for enhanced performance and capacity.
  • Effective, from 5.0 pH to 9.0 pH
  • Highest flow rate of any standard iron removal media.

Operating Conditions

Active Ingredient 75-85% Manganese Dioxide
Service Flow 6 gpm/cu.ft.
Freeboard 30-50%
Backwash rate 12-15 gpm/sq.ft @ 60F
Bed depth 20 inch Minimum
pH Range 5.0 – 9.0
Screen size 12 x 40
Bulk density 114 lbs/cu.ft.
Removal Capacity
Iron 27 ppm
Hydrogen Sulfide 17 ppm
Manganese 11 ppm


Comparative Information

Product Name Active Ingredient Relative Life
Greensand 0.5% Manganese Dioxide 50 xbirm
Filox-R 75-85% Manganese Dioxide 7500X birm


Ordering Information

Part Number Description Cubic Foot Weight (Lbs.) Package Pallet Qty.
A8033 Filox-R™ media 0.5 57 Bag 37
The use of additional oxidizing agents (oxygen, chlorine, ozone, hydrogen peroxide, potassium permanganate, etc.) is recommended. Oxidizers will not adversely affect Filox-R™. As a matter of fact, they will enhance its performance. They oxidize the media, which enables Filox-R™ to perform quicker and keep cleaner. It is always a safe practice to install an oxidation method upstream (in front) of the Filox-R™ bed.

Testing For ORP
Oxidation Reduction Potential (ORP) can be the most important factor to take into consideration in certain waters. Highly reducing waters may cause premature exhaustion or even destruction of the Filox-R™ bed. Precautions can be taken prior to installation that can prevent ORP problems. Use one of the screening tests and follow the instructions below if the subject water has reducing properties that will require additional oxidants.

Simple test
Mix 1.75 ounces (50 grams) water with 0.75 ounces (22 grams) of potassium permanganate crystals. Then take 2 drops of the mixture and stir into a fresh 1/4 gallon (1 liter) sample of the subject water. Let the subject water stand for 15 minutes. If the pink color remains, Filox-R™ can be installed without additional oxidants. If the pink color disappears, additional oxidants will be needed for Filox-R™ to function properly.

ORP Meter test
Note: Must use a calibrated ORP meter. Any reading that is above a negative 170 millivolts indicates that Filox-R™ can be used effectively without additional oxidants. Any reading falling below a negative 170 millivolts indicates that additional oxidants will be required.